RDZGH-120/X DC Hipot Tester

The RDZGH-120/X DC High Voltage Generator adopts advanced PWM control, high-frequency power technology, and voltage-current dual closed-loop feedback to provide stable DC high voltage output with low ripple and high accuracy. Equipped with high-quality IGBT components and high-frequency rectifier diodes, it features a compact design, high efficiency, and reliable performance for field testing. With multiple protections including over-current, over-voltage, zero-position, and breakdown protection, the generator ensures safe operation of both users and equipment. The intelligent 0.75U function supports zinc oxide arrester testing, while its lightweight design and easy operation make it ideal for DC insulation strength and leakage current tests of high-voltage equipment.
Model:RDZGH-120/X

Related Products

微信图片_20260316095222_385_1582
RDB-III_6
图片1
b1ae606fccdf5a17e97ec630d04d6567

Product Features

 

1. Advanced PWM technology combined with voltage and current dual closed-loop control ensures stable high-voltage output with minimal ripple. The precise adjustment system provides accurate testing performance, with a voltage resolution of 0.1kV and current resolution of 1μA.

2. The device is equipped with comprehensive safety protection functions, including zero-start protection, over-current protection, over-voltage protection, and breakdown protection. The fast protection response effectively safeguards both operators and test equipment.

3. The built-in intelligent 0.75U function automatically sets the voltage and current to the required testing level, improving efficiency and simplifying zinc oxide arrester testing procedures.

4. The zero-voltage start design features a high-precision multi-turn potentiometer, allowing smooth voltage regulation and accurate output control.

5. The digital dial switch provides a convenient and precise method for setting the overvoltage protection value.

6. With an integrated structure, the control unit and high-voltage cylinder are installed in a compact portable case. The high-frequency rectification technology helps reduce equipment size while improving overall efficiency.

7. Premium components and specially designed insulation materials ensure excellent electrical performance, strong moisture resistance, and stable long-term operation.

8. The user-friendly interface, well-organized control panel, and straightforward operation make the instrument easy to use for on-site high-voltage testing.

 

FAQs

 

1. What types of power equipment require DC high voltage testing?
A: DC high voltage testing is commonly used for power cables, transformers, motors, generators, switchgear, insulators, and surge arresters to evaluate insulation performance.

2. What is the difference between a DC high voltage generator and an AC withstand voltage tester?
A: A DC high voltage generator applies direct current voltage and is mainly used for insulation resistance evaluation and leakage current measurement, while an AC withstand voltage tester is used to simulate AC operating conditions.

3. Why is leakage current measurement important during DC high voltage testing?
A: Leakage current measurement helps identify insulation aging, moisture, contamination, and potential defects in electrical equipment before failures occur.

4. How long does a typical DC high voltage insulation test take?
A: The testing time depends on the equipment type, voltage level, and applicable standards. Engineers usually follow manufacturer recommendations and industry testing requirements.

5. Can a DC high voltage generator be used for outdoor testing?
A: Yes. Portable DC high voltage generators are designed for field applications and can be used for on-site testing in substations, power plants, and industrial facilities under suitable environmental conditions.

6. What should be checked before using a DC high voltage tester?
A: Before testing, users should inspect the test connections, grounding system, power supply, equipment condition, and ensure all safety procedures are followed.

7. Why is portability important for high voltage testing equipment?
A: Portable test equipment allows engineers to perform inspections at different locations, reducing transportation difficulties and improving maintenance efficiency.

8. What maintenance is required for a DC high voltage generator?
A: Regular maintenance includes checking cables and connectors, verifying calibration accuracy, inspecting insulation components, and keeping the equipment clean and dry.

9. How does a DC high voltage tester help prevent electrical equipment failures?
A: By detecting insulation weaknesses and abnormal leakage current, a DC high voltage tester helps engineers identify potential problems before they cause unexpected equipment shutdowns.

10. What industries commonly use DC high voltage generators?
A: DC high voltage generators are widely used in electric utilities, power transmission companies, railway systems, industrial plants, research laboratories, and electrical equipment manufacturers.

Technical Parameters

 

Parameter 120/2 120/3 120/5
Rated Voltage 120 kV 120 kV 120 kV
Rated Current 2 mA 3 mA 5 mA
Rated Power 240 W 360 W 600 W
Weight 10 kg 10 kg 10 kg
Dimensions 565 × 390 × 190 mm 565 × 390 × 190 mm 565 × 390 × 190 mm
Cylinder Height 535 mm 535 mm 535 mm
Output Voltage Accuracy ±(1.0%rdg ± 2dgt) ±(1.0%rdg ± 2dgt) ±(1.0%rdg ± 2dgt)
Output Current Accuracy ±(1.0%rdg ± 2dgt) ±(1.0%rdg ± 2dgt) ±(1.0%rdg ± 2dgt)
Ripple Coefficient ≤0.5% ≤0.5% ≤0.5%
Operating Mode Intermittent operation, rated load for 30 minutes Intermittent operation, rated load for 30 minutes Intermittent operation, rated load for 30 minutes
Overload Capacity No-load voltage can exceed rated voltage by 10% for 10 minutes; Maximum charging current: 1.25 times rated current No-load voltage can exceed rated voltage by 10% for 10 minutes; Maximum charging current: 1.25 times rated current No-load voltage can exceed rated voltage by 10% for 10 minutes; Maximum charging current: 1.25 times rated current
Power Supply AC 220V ±10%, 50Hz AC 220V ±10%, 50Hz AC 220V ±10%, 50Hz
Working Environment Temperature: -10℃ to 40℃; Relative humidity: ≤85% (25℃, no condensation); Altitude: <1500 m Temperature: -10℃ to 40℃; Relative humidity: ≤85% (25℃, no condensation); Altitude: <1500 m Temperature: -10℃ to 40℃; Relative humidity: ≤85% (25℃, no condensation); Altitude: <1500 m