RDXZL-800kVA/50kV Power Frequency Series Resonant Test System is designed for high voltage AC withstand testing of transformers, power cables, GIS, switchgear, and other electrical equipment. With advanced series resonance technology, it provides stable sine wave output, reduces power requirements, and improves testing efficiency and safety. The system features automatic tuning, multiple operation modes, digital data storage, and DSP-based control for easy operation and accurate test results. Its compact design and reliable performance make it an ideal solution for high voltage insulation testing in power systems.
Model:RDXZL-800kVA/50kV

Related Products

Series Resonant Device
Power Frequency Series Resonant Test System
RDGYB-JD1000_1
RDVLF-Z80Y_11_副本

Product Features

 

1. The required power supply capacity is significantly reduced, reaching only 1/Q of the actual test capacity.

2. The equipment features a much smaller size and lighter weight, reduced to approximately 1/10–1/30 compared with traditional testing systems.

3. The output voltage achieves a high-quality sine waveform by minimizing waveform distortion.

4. It can effectively identify insulation defects while avoiding excessive short-circuit current that may damage the fault location.

5. The system eliminates recovery overvoltage during testing, ensuring safer operation.

6. Three operating modes are provided, including automatic operation, manual control, and automatic tuning with manual voltage boosting, allowing flexible user selection.

7. Test data can be digitally saved and printed remotely for convenient record management.

8. Automatic frequency scanning is supported, with test results clearly displayed on the LCD screen.

9. Based on advanced DSP platform technology, the system provides a more user-friendly human-machine interface for easier operation.

 

Compositions of Testing System

Serial No. Equipment Name Model and Specification Unit Quantity
1 Excitation Transformer RDJLB-80kVA/5kV/7kV/0.4kV Unit 1
2 Resonant Operating Console RDXZL-80kW/380V Unit 1
4 Adjustable Reactor RDDK-500kVA/50kV 8~50H Unit 1
5 Fixed Reactor RDDK-300kVA/50kV 20H Unit 1
6 AC Voltage Divider FRC-50kV Set 1
7 Test Cable Set 1

 

FAQs

 

Q1: What is the RDXZL-800kVA/50kV Power Frequency Series Resonant Test System used for?
A: The RDXZL-800kVA/50kV Power Frequency Series Resonant Test System is mainly used for AC withstand voltage testing of high voltage electrical equipment, including transformers, cables, GIS, switchgear, and other power system components.

Q2: What is the maximum output capacity of the 800kVA series resonant test system?
A: This system provides a rated output capacity of 800kVA with a maximum rated voltage of 50kV, suitable for high voltage insulation withstand testing applications.

Q3: What are the advantages of using a power frequency series resonant test system?
A: A power frequency series resonant test system reduces the required power supply capacity, lowers equipment size and weight, improves testing efficiency, and provides a high-quality sinusoidal output waveform.

Q4: How does the RDXZL-800kVA/50kV series resonant tester improve testing safety?
A: The system can accurately locate insulation weaknesses while limiting excessive short-circuit current, preventing damage to fault points and improving overall testing safety.

Q5: Why is the power requirement lower than traditional AC withstand voltage test equipment?
A: Due to the series resonance principle, the system only requires approximately 1/Q of the test capacity power supply, which significantly reduces the required input power.

Q6: What type of waveform does the RDXZL-800kVA/50kV resonant test system provide?
A: The system generates a high-quality sine wave output voltage by reducing waveform distortion, ensuring accurate and reliable AC withstand voltage testing.

Q7: Can the 800kVA series resonant test system be used for transformer testing?
A: Yes, it is suitable for transformer insulation withstand voltage tests, including high voltage AC testing during manufacturing, commissioning, and maintenance.

Q8: Is this series resonant test equipment suitable for cable withstand voltage testing?
A: Yes, the system can be used for high voltage cable testing, including power cable insulation evaluation and AC withstand voltage verification.

Q9: What operating modes are available on the RDXZL-800kVA/50kV test system?
A: The system provides three operating modes: automatic mode, manual mode, and automatic tuning with manual voltage boosting mode, allowing flexible operation based on testing requirements.

Q10: Does the series resonant test system support automatic frequency tuning?
A: Yes, the system supports automatic frequency scanning and resonance point searching, with test results displayed clearly on the LCD screen.

Excitation Transformer RDJLB-80kVA/5kV/7kV/0.4kV

 

Item Specification
Rated Capacity 80 kVA
Input Voltage 380V, Three-phase
Input Current 200A
Overcurrent Capacity 110% of rated current (In) for 1 minute
Output Voltage 5 kV / 7 kV
Structure Type Oil-immersed self-cooling type

Control Console RDXZL-80kW/380V (with built-in electric voltage regulator)

 

Item Specification
Rated Output Capacity 80 kW
Operating Power Supply 380V, Three-phase, Power Frequency
Output Voltage 0–430V
Rated Input Current 210A
Rated Output Current 210A
Output Waveform Sine Wave
Voltage Measurement Accuracy 1.5%
Operating Time 5 minutes continuous operation under rated capacity
Maximum Component Temperature Rise ≤65K after 5 minutes continuous operation at rated capacity
Noise Level ≤50 dB

 

High-Voltage Adjustable Reactor RDDK-500kVA/50kV

 

Item Specification
Rated Capacity 500 kVA
Rated Voltage 50 kV
Rated Current 10 A
Inductance 8–50 H per unit
Quality Factor (Q) ≥30 (at 50 Hz)
Overvoltage Capacity 1.1 times rated voltage (1 minute)
Structure Type Oil-immersed, adjustable iron-core type

 

Fixed Reactor RDDK-300kVA/50kV

 

Item Specification
Rated Capacity 300 kVA
Rated Voltage 50 kV
Rated Current 6 A
Inductance 20 H per unit
Quality Factor (Q) ≥30 (at f = 50 Hz)
Overvoltage Capacity 1.1 times rated voltage (1 minute)
Structure Type Dry type

 

AC Voltage Divider FRC-50kV

 

Item Specification
Rated Voltage AC 50 kV
Voltage Division Ratio 1000:1
Measurement Accuracy AC Effective Value Class 1.0