Wrindu

IEC61850 Digital Relay Protection Tester with Flexible Multi-Channel Configuration

The device features 12 small-signal output channels, 10 digital input contacts, and 8 digital output contacts, fully supports IEC61850-9-1, IEC61850-9-2, IEC61869-9 and GOOSE communication, and offers a standard 7 voltage + 6 current configuration with optional flexible channel combinations for versatile relay protection testing applications.
Model:RDJB-802Y

Related Products

47f0d3a7338b9edd784317286d7bc244_副本
RDZGH-200-10_2
AC Resonance Withstand Testing Device
a645464c53f7c913b2f52673622712b9

PRODUCT FEATURES

 

1. The system is designed with overload alarm, transient surge protection, and overtemperature shutdown functions to guarantee safe and reliable operation.

2. All AC/DC output channels are equipped with independent hardware overload protection and complete signal isolation.

3. It fully supports IEC61850-9-1, IEC61850-9-2, IEC61869-9, and GOOSE protocols for modern digital substation testing.

4. Integrated Ethernet and USB interfaces enable seamless networking, data transfer, and remote operation.

5. A built-in 35W auxiliary DC power supply delivers stable 0–265V output for extended testing needs.

6. The unit provides 10 binary input channels and 8 binary output channels with dry and wet contact compatibility.

7. All binary channels adopt full galvanic isolation to ensure strong anti-interference capability and high reliability.

8. The analog output section includes 7 voltage channels and 6 current channels with high-precision control performance.

9. The system supports high-current output up to 120A with excellent stability and measurement accuracy.

10. Voltage phase accuracy is maintained within ≤0.2°, ensuring precise test results.

11. The software enables comprehensive protection testing, including overcurrent, differential, distance, and frequency functions.

12. It also supports COMTRADE file import, sequence control, ramp testing, and automatic test report generation.

 

FAQs

 

Q1: What safety protection functions does the test system include?
A: It includes overload alarm, transient protection, and overtemperature shutdown to ensure safe operation.

Q2: How does the system protect AC and DC output channels?
A: All channels have independent hardware overload protection and full signal isolation for safety and stability.

Q3: Does the tester support IEC61850 communication standards?
A: Yes, it supports IEC61850-9-1, IEC61850-9-2, IEC61869-9, and GOOSE protocols for digital substations.

Q4: What analog output channels does the system provide?
A: It provides 7 voltage channels and 6 current channels with high precision and stable performance.

Q5: Can the system handle advanced protection testing functions?
A: Yes, it supports overcurrent, differential, distance, frequency testing, plus COMTRADE import and automatic reporting.

TECHNICAL PARAMETERS

 

Category Item Specification
AC Current Source Channels 6 independent channels
Output Range 0–30 A per phase (RMS ×6)
Resolution 0–0.3A: 0.03 mA; 0.3–3A: 0.3 mA; 3–30A: 3.0 mA
Accuracy ≤0.1% (0.05A–30A)
Frequency Range 0–1000 Hz (static), 0–3000 Hz (dynamic)
Frequency Resolution 0.001 Hz
Frequency Accuracy ≤0.001 Hz
THD ≤0.5%
Response Time ≤50 μs
Load Capacity 5A ≥60 VA; 30A ≥350 VA
Output Duration ≤10A continuous; 10–20A ≥100s; 20–30A ≥20s; 15A ≥10min
Channels 7 independent channels
Output Range 0–300 V per phase
Resolution 0–10V: 1 mV; 10–300V: 4 mV
Accuracy ≤0.1% (2V–300V)
Frequency Range 0–1000 Hz (static), 0–3000 Hz (dynamic)
Frequency Resolution 0.001 Hz
THD ≤0.5%
Response Time ≤50 μs
Load Capacity 57.735V ≥30 VA; 300V ≥70 VA
Output Mode Continuous output
Synchronization Sync Time ≤10 μs
Phase Range -360° to +360°
Phase Resolution 0.05°
Phase Accuracy ≤0.2°
Closing Angle Range 0°–360°
Closing Angle Resolution 0.05°
Closing Angle Accuracy ≤0.2°
DC Current Source Channels 6 channels
Output 20A per phase ×6
Resolution 0.03 mA / 0.3 mA / 3.0 mA
Accuracy ≤0.1% (0.01A–30A)
Ripple Factor ≤0.5%
Load Capacity 5A ≥75W; 30A ≥450W
DC Voltage Source Channels 7 main + 1 auxiliary
Main Output 176V per phase ×7
Auxiliary Output 0–265V DC, ≥35W
Resolution 5 mV
Accuracy ≤0.5%
Ripple Factor ≤0.5%
Digital Input Channels 10 channels
Type Dry contact (0V), Wet contact (15–290V DC)
Isolation Full galvanic isolation
Time Resolution 10 μs
Digital Output Channels 8 channels
Rating 300V AC/DC withstand
Control Software controllable
Isolation Full galvanic isolation
IEC61850 Function Protocols IEC61850-9-1 / 9-2 / IEC61869-9
Communication GOOSE & SMV
File Support ICD import
Signal Output 12-channel 0–7V small signal
Accuracy 0.05%
General Parameters Power Supply 110–265V AC / 110–220V DC, 45–65Hz
Operating Temp -5°C to +50°C
Weight 12 kg
Dimensions 365 × 200 × 450 mm
Interfaces Ethernet / Serial / USB